Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 354
Filter
1.
Chinese Journal of Orthopaedics ; (12): 55-61, 2023.
Article in Chinese | WPRIM | ID: wpr-993410

ABSTRACT

Objective:To investigate the clinical efficacy of preoperative three-dimensional (3D) reconstruction planning in total hip arthroplasty for development dysplasia of the hip secondary to osteoarthritis.Methods:A total of 80 patients with osteoarthritis secondary to Crowe I-III developmental dysplasia of the hip who underwent primary unilateral total hip arthroplasty from October 2019 to March 2021 were retrospectively analyzed, including 18 males and 62 females and the mean age was 55.7±10.4 years (range 41-72 years). Forty patients in the 3D group, the prosthesis type and installation angle were planed on the 3D reconstruction software based on the full-length CT scan data of the lower limbs, and the length difference of the lower limbs and hip offset were calculated. Forty patients in the control group underwent preoperative planning using conventional film measurement, and lower limb length was judged based on the preoperative measurement data and intraoperative comparison of both lower limbs. The difference of postoperative leg length, hip offset, hip function score, operating time, intraoperative blood loss, and incidence of complications were compared between the two groups.Results:All 80 patients completed the surgery successfully and the follow-up time was up to 3 months after operation. The 3D group was better than the control group in operation time (70.9±7.7 min vs. 81.6±13.3 min, t=-4.91, P<0.001), the difference of postoperative lower limb length (2.78±1.31 cm vs. 5.35±2.15 cm, t=-5.74, P<0.001), and hip function score at 1 week after operation (75.67±3.35 vs. 67.35±4.21, t=12.33, P=0.002), with statistically significant differences. In the 3D group, 95% of acetabular prosthesis and 90% of femoral stem components were consistent with the planned model, while the rate were only 75% and 68% in the control group, and the difference was statistically significant (χ 2=7.51, P=0.023; χ 2=14.92, P=0.005). There were no intraoperative complications such as vascular and nerve injury, and no postoperative complications such as dislocation or periprosthetic infection in all 80 patients. Conclusion:3D preoperative planning assisted total hip arthroplasty in the treatment of Crowe I-III developmental dysplasia of the hip secondary to osteoarthritis can improve the accuracy of the operation, and has a good clinical effect on restoring the leg length and hip offset.

2.
Chinese Journal of Trauma ; (12): 138-144, 2023.
Article in Chinese | WPRIM | ID: wpr-992581

ABSTRACT

Objective:To investigate the effect of open reduction and internal fixation assisted by computer virtual surgery in the treatment of complex proximal humeral fracture.Methods:A retrospective case series study was performed on clinical data of 36 patients with complex proximal humeral fracture admitted to Dongfang Hospital Affiliated to Tongji University from January 2018 to June 2020. There were 13 males and 23 females, aged 22-86 years [(56.4±4.8)years]. They were all closed fractures. According to Neer classification, there were 20 patients with three-part fractures and 16 with four-part fractures. Precise pre-surgical designs made by using the digital orthopedic surgery planning system of the E-3D were applied to assist the implementation of precise fracture reduction and internal fixation with the locking plate. The fracture healing was observed. The effect of the real surgery assisted by the virtual surgical designs was assessed by comparing the humeral neck shaft angle and humeral head height measured at the virtual surgery and at day 1 after the real surgery. The humeral neck shaft angle, humeral head height, shoulder range of motion (abduction, external rotation and forward flexion), Constant shoulder function score and visual analogue score (VAS) were recorded at 1 day, 3 months and 12 months after the real surgery. The stability of the medial column was assessed at 1 day after the real surgery. The complications were recorded.Results:All patients were followed up for 12-38 months [(18.5±1.8)months]. The fracture showed bony union in all patients with the union time of 6.6-17.2 weeks [(10.2±1.0)weeks]. The humeral neck shaft angle and humeral head height showed no significant differences measured at the virtual surgery and at 1 day after the real surgery, and were also not significant different at 1 day, 3 months and 12 months after the real surgery (all P>0.05). At 3 months and 12 months after the real surgery, the shoulder abduction [(119.4±11.8)°, (155.3±13.7)°], external rotation [(37.6±6.3)°, (46.8±7.4)°], forward flexion [ (94.8±10.2)°, (126.9±1.6)°] and Constant function score [(66.8±8.4)points, (82.4±9.6)points] were all higher than those at 1 day after the real surgery [(53.8±4.5)°, (21.6±3.3)°, (44.6±7.8)°, (34.3±6.1)points], while the VAS [(4.1±0.5)points, (1.2±0.2)points] was lower than that at 1 day after the real surgery [(8.3±1.4)points] (all P<0.05). The medial column was stable in 34 patients and unstable in 2 at 1 day after the real surgery. Complications included screw cutting out in the articular surface in 1 patient and humeral head necrosis in 1. Conclusion:Treatment of complex proximal humeral fractures with open reduction and internal fixation assisted by computer virtual surgery is conducive to maintaining reduction effect, promoting shoulder joint function, relieving pain and reducing complications.

3.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 258-264, 2023.
Article in Chinese | WPRIM | ID: wpr-991739

ABSTRACT

Objective:To investigate the difference in left ventricular dysfunction between type 2 diabetes mellitus (T2DM) patients with hyperlipidemia and those without hyperlipidemia, and analyze the application value of three-dimensional speckle tracking technology.Methods:The clinical data of 70 patients with T2DM admitted to Heji Hospital Affiliated to Changzhi Medical College from January 2020 to June 2021 were retrospectively analyzed. Among these patients, 35 patients had hyperlipidemia and 35 patients had no hyperlipidemia. At the same time, 40 healthy subjects who concurrently underwent health checkups in the same hospital were included as healthy controls. All subjects underwent routine cardiac ultrasound and 3D-STE examinations. General clinical information and left ventricular function-related parameters, including global longitudinal strain, global circumferential strain, global area strain, and global radial strain were compared between healthy controls and T2DM patients with hyperlipidemia and those without hyperlipidemia.Results:The proportion of left ventricular remodeling increased in T2DM patients without hyperlipidemia, and the proportion of left ventricular hypertrophy was the highest in T2DM patients with hyperlipidemia. Global longitudinal strain and global circumferential strain in T2DM patients without hyperlipidemia were (-16.97 ± 2.59)% and (-17.41 ± 2.50)%, respectively, which were significantly higher than (-18.86 ± 2.46)% and (-18.71 ± 2.92)% in healthy controls ( t = 0.95, 0.57, both P < 0.05). Global longitudinal strain, global circumferential strain, and global area strain in T2DM patients with hyperlipidemia were (-14.98 ± 3.15)%, (-15.80 ± 3.16)%, (-27.17 ± 4.54)%, respectively, which were significantly higher than (-18.86 ± 2.46)%, (-18.71 ± 2.92)%, (-30.62 ± 4.02)% in healthy controls ( t = 0.46, 1.37, 0.98, all P < 0.05) and (-16.97 ± 2.59)%, (-17.41 ± 2.50)%, (-30.06 ± 3.59)% in T2DM patients without hyperlipidemia ( t = 0.37, 1.02, 0.77, all P < 0.05). Global radial strain in T2DM patients with hyperlipidemia was significantly higher than [(51.49 ± 8.94)%, t = 1.35, P < 0.05] in healthy controls and [(47.71± 8.46)%, t = 0.98, P < 0.05] in T2DM patients without hyperlipidemia. In patients with T2DM, fasting blood glucose and hyperlipidemia were independently correlated with all strain-related parameters. Conclusion:Hyperlipidemia can aggravate left ventricular remodeling and dysfunction in patients with T2DM and 3D-STE is one of the examination methods for subclinical left ventricular remodeling and dysfunction in T2DM patients with or without hyperlipidemia.

4.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 197-200, 2023.
Article in Chinese | WPRIM | ID: wpr-991726

ABSTRACT

Objective:To investigate the diagnostic value of thin-layer three-dimensional reconstruction technology combined with personalized scanning for benign and malignant solid solitary pulmonary nodules.Methods:The clinical data of 140 patients with solid solitary pulmonary nodules admitted to Jiangshan People's Hospital form January 2020 to July 2021 were retrospectively analyzed. These patients consisted of 40 patients with benign solid solitary pulmonary nodules (benign group) and 100 patients with malignant solid solitary pulmonary nodules (malignant group). All patients underwent thin-layer three-dimensional reconstruction combined with personalized scanning. The pulmonary nodule signs achieved by thin-layer three-dimensional reconstruction combined with personalized scanning and the diagnostic performance of the combined technology were compared between benign and malignant groups.Results:The proportions of patients with lung cavity sign, lobular sign, vascular convergence sign, vacuole sign, emphysema distribution sign, split pleura sign, and distal perforating vascular sign in the malignant group were 11.0%, 81.0%, 77.0%, 49.0%, 6.0%, 10.0% and 31.0%, respectively, and they were 42.5%, 62.5%, 55.0%, 27.5%, 20.0%, 32.5%, and 5.0%, respectively in the benign group ( χ2 = 15.80, 5.00, 5.66, 4.55, 4.76, 8.96, 9.33, all P < 0.05). The most sensitive sign was lobular sign, which had the highest efficiency, up to 82.0%, in differentiating benign and malignant pulmonary nodules. Conclusion:Lung cavity sign, lobular sign, vascular convergence sign, vacuole sign, emphysema distribution sign, split pleura sign, and distal perforating vascular sign differ greatly between patients with benign and malignant solid solitary pulmonary nodules. Lobular sign has the highest sensitivity in differentiating benign and malignant solid solitary pulmonary nodules. Thin-layer three-dimensional reconstruction combined with personalized scanning has a diagnostic value for benign and malignant solid solitary pulmonary nodules.

5.
International Journal of Surgery ; (12): 49-55,C3,C4, 2023.
Article in Chinese | WPRIM | ID: wpr-989404

ABSTRACT

Objective:Three-dimensional simulation modeling technology was used to conduct three-dimensional reconstruction, classification and measurement for the anatomic structures of colorectal canal, tumor and key blood vessels in patients with rectal cancer before operation. And the accuracy of the data and information obtained for the prediction of anastomotic tension, important types of vascular variant, positioning of anatomical landmarks, etc. in laparoscopic-assisted radical resection of rectal cancer, and the guiding effect of operation was evaluated.Methods:The clinical data of 50 patients with laparoscopic-assisted radical resection of rectal cancer treated in the General Surgery Department, Beijing Ditan Hospital Capital Medical University from January 2019 to February 2021 were analyzed retrospectively, including 31 males and 19 females, aged from 42 to 83 years old, with an average age of (62.72 ±15.21) years. The patients were divided into two groups according to whether the patients underwent three-dimensional simulation reconstruction before operation. The patients who underwent abdomen pelvic enhancement CT and further three-dimensional reconstruction before surgery were taken as reconstruction group ( n=24), and the patients who were only routinely performed abdomen pelvic enhancement CT before operation were taken as control group ( n=26). For the patients in the reconstruction group, the CT images were modeled by Mimics software before operation, and the key data such as the length of colorectal and tumor, the correlation length of rigid structure of pelvic wall, the length of inferior mesenteric artery (IMA) from the bifurcation point of left and right arteria iliaca communis, the type and proportion of IMA variation, the length of left colonic artery (LCA) from the beginning of IMA and the distance between LCA and IMV were measured, and the consistency correlation coefficient (CCC) was analyzed with the actual data obtained during operation. And then the accuracy of three-dimensional simulation modeling technology for surgical guidance was evaluated. MedCalc 19.0 software was used for statistical analysis. Results:In the reconstruction group, regarding the data of each dimension of the model (intestinal tract, pelvic cavity, blood vessels) and the corresponding structural measurements during the operation, the consistent correlation coefficient (CCC) evaluation was more than 0.9. One case was predicted to have free splenic flexure of colon and one case actually had free splenic flexure of colon. The prediction accuracy was 100%. The IMA variants in the reconstruction group were divided into 4 types, all of which were verified by operation. Compared with the control group, the operation time ( P=0.011) and the location time (IMA, P=0.043; LCA, P=0.007; IMV, P=0.034) of each vessel in the reconstruction group were shorter, and the amount of intraoperative blood loss was less ( P=0.017). Conclusion:The application of three-dimensional simulation modeling technology before operation is helpful for the operator to accurately predict the intraoperative anastomotic tension, the type of IMA variation and the related diameter length, based on which the accurate operation plan can be made to guide the operation.

7.
Journal of Clinical Hepatology ; (12): 457-462, 2023.
Article in Chinese | WPRIM | ID: wpr-964815

ABSTRACT

Hepatic alveolar echinococcosis (HAE) is a parasitic disease caused by Echinococcus multilocularis infection and has wide distribution and great harm in China. At present, ultrasound, CT, and MRI are the main radiological examination methods for HAE, with certain limitations in preoperative diagnosis and evaluation. This article introduces the guiding effect of three-dimensional visualization technique and its derivative technologies in the accurate diagnosis and preoperative evaluation of HAE, so as to provide help for the clinical diagnosis and treatment of HAE in the future.

8.
Journal of Peking University(Health Sciences) ; (6): 174-180, 2023.
Article in Chinese | WPRIM | ID: wpr-971292

ABSTRACT

OBJECTIVE@#To explore an efficient and automatic method for determining the anatomical landmarks of three-dimensional(3D) mandibular data, and to preliminarily evaluate the performance of the method.@*METHODS@#The CT data of 40 patients with normal craniofacial morphology were collected (among them, 30 cases were used to establish the 3D mandibular average model, and 10 cases were used as test datasets to validate the performance of this method in determining the mandibular landmarks), and the 3D mandibular data were reconstructed in Mimics software. Among the 40 cases of mandibular data after the 3D reconstruction, 30 cases that were more similar to the mean value of Chinese mandibular features were selected, and the size of the mandibular data of 30 cases was normalized based on the Procrustes analysis algorithm in MATLAB software. Then, in the Geomagic Wrap software, the 3D mandibular average shape model of the above 30 mandibular data was constructed. Through symmetry processing, curvature sampling, index marking and other processing procedures, a 3D mandible structured template with 18 996 semi-landmarks and 19 indexed mandibular anatomical landmarks were constructed. The open source non-rigid registration algorithm program Meshmonk was used to match the 3D mandible template constructed above with the tested patient's 3D mandible data through non-rigid deformation, and 19 anatomical landmark positions of the patient's 3D mandible data were obtained. The accuracy of the research method was evaluated by comparing the distance error of the landmarks manually marked by stomatological experts with the landmarks marked by the method of this research.@*RESULTS@#The method of this study was applied to the data of 10 patients with normal mandibular morphology. The average distance error of 19 landmarks was 1.42 mm, of which the minimum errors were the apex of the coracoid process [right: (1.01±0.44) mm; left: (0.56±0.14) mm] and maximum errors were the anterior edge of the lowest point of anterior ramus [right: (2.52±0.95) mm; left: (2.57±1.10) mm], the average distance error of the midline landmarks was (1.15±0.60) mm, and the average distance error of the bilateral landmarks was (1.51±0.67) mm.@*CONCLUSION@#The automatic determination method of 3D mandibular anatomical landmarks based on 3D mandibular average shape model and non-rigid registration algorithm established in this study can effectively improve the efficiency of automatic labeling of 3D mandibular data features. The automatic determination of anatomical landmarks can basically meet the needs of oral clinical applications, and the labeling effect of deformed mandible data needs to be further tested.


Subject(s)
Humans , Imaging, Three-Dimensional/methods , Mandible/diagnostic imaging , Software , Algorithms , Anatomic Landmarks/anatomy & histology
9.
Journal of Peking University(Health Sciences) ; (6): 156-159, 2023.
Article in Chinese | WPRIM | ID: wpr-971289

ABSTRACT

OBJECTIVE@#To investigate the difference in sensitivity between X-ray and three-dimensional reconstruction of computed tomography (3D-CT) for the diagnosis of distal fibular avulsion fracture, and the radiographic presentation of the ossicle.@*METHODS@#From January to October 2018, 92 patients with distal fibular avulsion fracture were visited for surgical treatment in Department of Sports Medicine, Peking University Third Hospital, and 60 cases were finally enrolled according to the inclusion and exclusion criteria. Intraoperative detection was regarded as the gold standard, and the diagnostic sensitivity of preoperative ankle X-ray and 3D-CT for the distal fibular avulsion fractures was statistically determined. The ossicle maximum diameter as well as the degree of its displacement were also measured. On 3D-CT, the distance from the ossicle center point to the anterior fibular tuberosity (a), the distance to the fibular tip (b), and the a/b value was used to present the ossicle displacement.@*RESULTS@#Among the 60 patients, 36 and the 52 patients were correctly detected by X-ray and 3D-CT, respectively, and the sensitivities was 60.0% and 86.7%, respectively (P=0.004). The mean diameter of the ossicle on X-ray and 3D-CT was (9.2±3.9) mm and (10.5±3.2) mm, respectively. The mean distance from the ossicle center to the anterior fibular tuberosity (a) was (17.5±3.6) mm and the mean distance to the fibular tip (b) was (17.4±4.8) mm, with mean a/b values of 1.1±0.7. The intraclass correlation coefficients (ICC) for each measurement ranged from 0.891-0.998 with a high degree of consistency.@*CONCLUSION@#Compared with X-ray, 3D-CT has higher sensitivity in diagnosing distal fibular avulsion fractures, can help clinicians evaluate ossicle's location and choose surgical methods, and is recommended to be performed in patients with suspected distal fibula avulsion fractures in clinical practice.


Subject(s)
Humans , Fibula/surgery , Fractures, Avulsion , Ankle , X-Rays , Imaging, Three-Dimensional , Ankle Fractures , Ankle Joint , Tomography, X-Ray Computed
10.
Chinese Journal of Digestive Endoscopy ; (12): 196-200, 2023.
Article in Chinese | WPRIM | ID: wpr-995374

ABSTRACT

Objective:To evaluate the application of three-dimensional (3D) imaging device to colonoscopy.Methods:A total of 60 patients who underwent painless colonoscopy in Beijing Friendship Hospital, Capital Medical University from November to December, 2019 were enrolled and divided into 2 groups according to random code. Each patient underwent colonoscopy twice, while 2D colonoscopy was used for cecal intubation. Thirty patients were assigned to the experimental group (primary withdrawal used 3D colonoscopy, and secondary withdrawal used 2D colonoscopy), and 30 others to the control group (primary withdrawal used 2D colonoscopy, and secondary withdrawal used 3D colonoscopy). The detection of polyps, the withdrawal time, operating experience, image quality and complication were evaluated in the two groups.Results:The polyp detection rate at the first colonoscopy in the experimental group was 77.3% (17/22), which was higher than 43.5% (10/23) in the control group ( χ2=5.351, P=0.021). Ten operators in the experimental group had dizziness, while the operators in the control group had no dizziness ( P=0.001). There were no significant differences between the two groups in the polyp diameter [0.50 (0.70) cm VS 0.30 (0.20) cm, U=57.000, P=0.170], withdrawal time (4.6±1.5 min VS 5.2±1.9 min, t=-1.189, P=0.239) or image quality (27 cases with 3 points in the identification of lesion nature, and 28 cases with 3 points in the identification of duct both in the two groups, P=1.000) at the first colonoscopy. No complication occurred in either group. Conclusion:Application of 3D imaging device is feasible for colonoscopic polyp detection, and it can be used in clinical practice.

11.
Chinese Journal of Geriatrics ; (12): 783-788, 2023.
Article in Chinese | WPRIM | ID: wpr-993892

ABSTRACT

Objective:To investigate the characteristics of anorectal dynamics in elderly patients with functional defecation disorders(FDD), and to provide a basis for their diagnosis, treatment and prevention.Methods:In this retrospective study, 226 patients with FDD receiving 3D high-resolution anorectal manometry were divided into an elderly group(93 cases)and a non-elderly group(133 cases). Results from anorectal manometry parameters were compared and analysis of patterns of anorectal pressure changes in elderly participants based on sex, the Bristol stool classification and clinical symptoms was conducted.Results:The resting anal pressure, rectal pressure and anal relaxation rate were lower( t=-3.407, -2.051, Z=2.548, P=0.001, 0.040, 0.011)and the volume of first sensation was higher( t=1.998, P=0.047)in the elderly group than in the non-elderly group.The maximum anal squeezing pressure, residual anal pressure and maximum tolerated volume were higher( t=4.589, 4.730, 2.025, all P<0.05), whereas the anal relaxation rate and anorectal pressure gradient were lower in elderly men than in elderly women( Z=4.059, t=-3.714, P<0.001 for both). Regarding the types of FDD, both the elderly group and the non-elderly group were dominated with type Ⅱ defecation disorder, with more men than women having type Ⅱ defecation disorder in the elderly group( χ2=10.343, P=0.001). In cases of paradoxical sphincter contraction during simulated defecation, the incidence in the elderly group was 80.65%(75/93), which was higher than 68.42%(91/133)in the non-elderly group( χ2=4.194, P=0.041). The volume of first sensation, volume of first defecation sensation, and maximum tolerated volume of patients in the elderly group without the urge to defecate were(59.86±23.84)ml, (96.76±34.61)ml, and(144.32±30.57)ml, respectively, higher than those of patients with the urge to defecate(46.79±17.20)ml, (75.26±28.75)ml, and(120.00±40.28)ml( t=-2.241, -2.493, -2.891, P=0.027, 0.014, 0.005). The rectal pressure(26.52±16.08)mmHg of patients with defecation dyssynergia was lower than that of patients without defecation dyssynergia(39.91±8.82)mmHg(1 mmHg=0.133 kPa)( t=-3.128, P=0.002), while the resting anal pressure of patients with defecation dyssynergia(90.60±28.44)mmHg was higher than that of patients without defecation dyssynergia(73.65±27.10)mmHg( t=-2.201, P=0.030). The resting anal pressure and maximum anal squeezing pressure in patients with anal blockage sensation[(87.11±24.64)mmHg, (149.28±48.29)mmHg]were higher than those in patients without anal blockage sensation[(72.43±20.02)mmHg, (121.76±26.35)mmHg]( t=2.954、3.066, P=0.004、0.003). There was no significant difference in values from parameters of anorectal dynamics between patients with different Bristol stool types, with and without incomplete defecation or with different degrees of abdominal distension(all P>0.05). Conclusions:Anorectal dynamics in patients with FDD are characterized by paradoxical anal sphincter movements, but older patients with FDD are mainly characterized by inadequate rectal propulsion, pelvic floor muscle dysfunction and reduced rectal sensitivity.

12.
Braz. j. oral sci ; 21: e225924, jan.-dez. 2022. ilus
Article in English | LILACS, BBO | ID: biblio-1355003

ABSTRACT

Aim: To assess the reliability and validity of morphometric features on 3D digital models produced by scanning maxillary dental casts of Malaysian Malay subjects. Methods: Dental casts of 20 subjects were scanned using a 3D laser scanner (Next Engine Inc., Santa Monica, California, USA). The palatal rugae morphometric features were assessed on the resulting 3D models using 3-Matic Research 9.0 software (Materialise NV, Heverlee, Belgium). The assessments were repeated by the first and second authors to assess the intra- and interexaminer reliability, respectively. Rugae morphometric features were also evaluated on the conventional plaster models to assess the validity of the 3D method. Results: Kappa values of the validity ranged from 0.807 to 0.922 for rugae shape, size category and direction. The intraclass correlation coefficient (ICC) for rugae number validity was 0.979. For intra-examiner reliability, kappa values ranged from 0.716-1.000 for rugae shape, size category and direction. The ICC for rugae number intra-examiner reliability was 0.949. Kappa values of interexaminer reliability for rugae shape, size category and direction were 0.723-885, while the ICC of rugae number was 0.896. Conclusion: Palatal rugae analyses on 3D digital models scanned by the 3D Next Engine laser scanner using 3-Matic Research 9.0 software are valid and reliable


Subject(s)
Palate , Forensic Anthropology , Imaging, Three-Dimensional , Forensic Dentistry
13.
Braz. j. oral sci ; 21: e227903, jan.-dez. 2022. ilus
Article in English | LILACS, BBO | ID: biblio-1355005

ABSTRACT

Aim: To evaluate the accuracy and the validity of orthodontic diagnostic measurements, as well as virtual tooth transformations using a generic open access 3D software compared to OrthoAnalyzer (3Shape) software; which was previously tested and proven for accuracy. Methods: 40 maxillary and mandibular single arch study models were duplicated and scanned using 3Shape laser scanner. The files were imported into the generic and OrthoAnalyzer software programs; where linear measurements were taken twice to investigate the accuracy of the program. To test the accuracy of the program format, they were printed, rescanned and imported into OrthAnalyzer. Finally, to investigate the accuracy of editing capabilities, linear and angular transformation procedures were performed, superimposed and printed to be rescanned and imported to OrthoAnalyzer for comparison. Results: There was no statistically significant difference between the two groups using the two software programs regarding the accuracy of the linear measurements (p>0.05). There was no statistically significant difference between the different formats among all the measurements, (p>0.05). The editing capabilities also showed no statistically significant difference (p>0.05). Conclusion: The generic 3D software (Meshmixer) was valid and accurate in cast measurements and linear and angular editing procedures. It can be used for orthodontic diagnosis and treatment planning without added costs


Subject(s)
Software , Casts, Surgical , Imaging, Three-Dimensional , Models, Dental
14.
Braz. dent. j ; 33(3): 38-46, July-Sept. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384033

ABSTRACT

Abstract This study evaluated the Reciproc R25 and Pro-R 25 instruments in unused condition, after one and a second use in endodontic retreatment employing a noncontact 3D light interferometer profiler, scanning electron microscopy (SEM) and cyclic fatigue tests. Twenty single-root teeth were instrumented with Reciproc R25 and filled with gutta-percha and sealer. A 3D profiler with a 20x objective using the Mx™ software was used to evaluate the cutting blade surfaces of Reciproc R25 and Pro-R 25 (n=5 per group) in unused condition, after the first and second uses in retreatment procedures. After retreatment, SEM was used to evaluate the topographic features of the used instruments. Cyclic fatigue tests were performed to compare new to used instruments. One-way ANOVA followed by Tukey test was used to compare the tested instruments before and after the first and second uses. Student t-test was used to compare the different instruments and for cyclic fatigue evaluation. No significant differences were observed in the cutting blade surfaces of Reciproc and Pro-R before and after one and two uses (p>0.05). Reciproc without use showed higher Sa and Sq when compared to Pro-R without use (p<0.05). No differences were observed between Reciproc and Pro-R after one and two uses (p>0.05). New and unused Reciproc showed longer time to fracture than Pro-R instruments (p<0.05), and only Pro-R showed differences between new and used instruments (p<0.05). Retreatment procedures with Reciproc and Pro-R did not change the surface topography of instruments. Reciproc had greater resistance to cyclic fatigue compared with Pro-R.


Resumo Este estudo avaliou os instrumentos Reciproc R25 e Pro-R 25 sem uso, após um primeiro e um segundo uso em retratamento endodôntico com perfilômetro 3D por interferometria de luz sem contato, microscópio eletrônico de varredura (MEV) e testes de fadiga cíclica. Vinte dentes unirradiculares foram instrumentados com Reciproc R25 e obturados com guta-percha e cimento endodôntico. Um perfilômetro 3D com uma objetiva 20x usando o software Mx ™ foi usado para avaliar as superfícies da lâmina de corte do Reciproc e Pro-R (n = 5 por grupo) na condição sem uso, após o primeiro e após um segundo uso em procedimentos de retratamento. Após retratamento, o MEV foi usado para avaliar as características topográficas dos instrumentos utilizados. Testes de fadiga cíclica foram realizados para comparar instrumentos novos com instrumentos usados. O teste One-way ANOVA seguido pelo teste de Tukey foi usado para comparar os instrumentos testados nos diferentes estágios. Para comparar os diferentes instrumentos e para avaliação de fadiga cílcica, foi utilizado o Student t-test. Não foram observadas diferenças estatisticamente significantes nas superfícies das lâminas de corte dos instrumentos Reciproc e Pro-R antes e após um e dois usos (p> 0,05). O Reciproc na condição sem uso apresentou maior Sa e Sq quando comparado ao Pro-R (p <0,05). Não foram observadas diferenças entre Reciproc e Pro-R após um e dois usos (p> 0,05). O Reciproc sem uso apresentou maior tempo de fratura do que os instrumentos Pro-R (p<0,05), e apenas o Pro-R apresentou diferenças entre instrumentos novos e usados (p<0,05). Os procedimentos de retratamento com Reciproc e Pro-R não alteraram a topografia da superfície dos instrumentos. Reciproc apresentou maior resistência à fadiga cíclica em comparação com o Pro-R.

15.
Rev. Bras. Odontol. Leg. RBOL ; 9(1): 89-97, 2022-05-04.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1524606

ABSTRACT

A incorporação do chamado fluxo digital já é uma realidade na odontologia clínica, e suas vantagens podem ser incorporadas à Odontologia Forense. Particularmente, os escâneres, ou scanners intraorais (SIOs) geram modelos tridimensionais digitais em forma de arquivo que podem ser armazenados, analisados e comparados utilizando aplicativos próprios. Trata-se de técnica que obtém registros com agilidade e precisão, onde os dados podem ser obtidos, se necessário, no próprio local do encontro, como por exemplo, nos acidentes coletivos. O objetivo deste estudo é revisar a literatura sobre as aplicações mais recentes dos SIOs e dos arquivos por eles gerados na Odontologia Forense. Onze trabalhos foram selecionados para revisão. Os estudos mostram que as técnicas existentes se beneficiam do uso dos SIOs e dos modelos digitais, e que medidas exatas e precisas podem ser feitas digitalmente. Algoritmos de comparação e inteligências artificiais podem ser de grande contribuição para o processo de identificação, diminuindo a quantidade de suspeitos a serem comparados com uma determinada amostra e identificando restaurações metálicas. A técnica digital permite a diferenciação de gêmeos monozigóticos por análise das rugosidades palatinas. A identificação humana baseada apenas na análise física ou digital de marcas de mordida não é recomendada, pois é sujeita a viés do examinador


The digital workflow is already ubiquitous in the clinical dental practice, and its advantages can be incorporated to the forensic odontology. Intraoral scanners generate digital casts that can be stored, analyzed and compared using the proper software. It's a technique that swiftly and precisely registers the object of interest, and can be used on-site, if needed, in mass disasters, for example. The goal of this article is to review the most recent applications of the intraoral scanners and the digital files generated by them in the forensic odontology practice. Eleven articles were selected for revision. The studies demonstrate that the existing identification techniques can benefit from the use of intraoral scanners and digital casts, and measures can be taken digitally with precision and accuracy. Automated comparison algorithms and artificial intelligence models can be of great contribution to the identification process, decreasing the number of suspects that could match a sample and identifying metallic restorations. Digital analysis of palatal rugae was used successfully to identify monozygotic twins. Human identification relying solely on bitemark analysis, even with digital techniques, is not recommended, due to examiner bias

16.
Chinese Journal of General Surgery ; (12): 354-357, 2022.
Article in Chinese | WPRIM | ID: wpr-933645

ABSTRACT

Objective:To evaluate the application value of three-dimension digital subtraction angiography (3D-DSA) in the diagnosis and treatment of iliac vein compression syndrome (IVCS).Methods:A retrospective analysis was made on 171 patients with a tentative diagnosis of IVCS based on signs, symptoms, and finding of CTV or MRV, and iliac vein angiography. The diagnostic efficacy of MRV, 2D-DSA and 3D-DSA were analyzed. The imaging advantages of 3D-DSA in the diagnosis and treatment of IVCS were evaluated.Results:Ninty-three patients underwent MRV and 3D-DSA simultaneously, 101 patients had 2D-DSA and 3D-DSA simultaneously. 3D-DSA was taken as gold standard, the diagonotic sensitivity, specificity, Youden index of MRV was 75.61%, 72.73% and 0.48 respectively. The sensitivity, specificity, Youden index of 2D-DSA was 90.22%, 100% and 0.90 respectively. There are significant differences in the diagonotic sensitivity between MRV and 3D-DSA, 2D-DSA and 3D-DSA ( P<0.05). There is no significant difference in the diagonotic specificity between MRV and 3D-DSA, 2D-DSA and 3D-DSA ( P=1.000). In this study, we found that 3D-DSA has greater imaging evaluation advantages in preoperative evaluation, intraoperative guidance and immediate postoperative reexamination in the diagnosis and treatment of iliac vein disease. Conclusions:3D-DSA can improve the detection rate of IVCS, and has its advantage in imaging evaluation.

17.
Chinese Journal of Orthopaedics ; (12): 41-46, 2022.
Article in Chinese | WPRIM | ID: wpr-932807

ABSTRACT

Objective:To measure the anatomical parameters of three-dimensional available space of S 1 and S 2 vestibules on Chinese adults by imaging methods, and discuss their clinical values. Methods:Data of 200 cases of pelvic CT with complete posterior ring were collected from January 2015 to January 2021, included 110 males and 90 females. The ages ranged from 21 to 63 years (average, 40.72±10.70 years). Then the parameters of both the left vestibule and the right vestibule of S 1 and S 2 such as vestibular width, vestibular height and vestibular area were measured by the three-dimensional CT reconstructions. Statistical analyses were performed among the groups which were classified according to the gender, side of vestibule to compare the difference of vestibular morphological characteristics among different groups. Results:The average vestibular area of S 1 was 425.71± 45.07 mm 2 (range, 296.3-604.4 mm 2), which was 449.80±28.62 mm 2 (range, 338.3-604.4 mm 2) in males and 388.25±34.01 mm 2 (range, 296.3-498.4 mm 2) in females. The average vestibular width was 28.52±4.34 mm (range, 17.1-36.3 mm), 31.77±2.33 mm (range, 22.46-36.30 mm) in males and 24.55±2.55 mm (range, 17.1-26.1 mm) in females. The mean vestibular height was 21.05±2.29 mm (range, 17.5-32.0 mm), with 21.34±2.37 mm (range, 18.5-32.0 mm) of men and 20.69±1.60 mm (range, 17.5-25.6 mm) of women. The mean S 2 vestibular area was 230.19±35.57 mm 2 (range, 142.5-297.3 mm 2), which was 258.91±28.04 mm 2 (range, 218.3-297.3 mm 2) in males and 205.61±24.12 mm 2 (range, 142.5-258.6 mm 2) in females. The average vestibular width was 15.94±1.72 mm (range, 12.4-20.3 mm), 16.51±1.59 mm (range, 14.4-20.3 mm) in male and 15.25±1.63 mm (range, 12.4-18.1 mm) in female. The mean vestibular height was 14.30±1.20 mm (range, 12.9-17.8 mm), 15.49±1.46 mm (range, 13.6-17.8 mm) in males and 13.73±0.93 mm (range, 12.9-16.1 mm) in females. There were significant differences in vestibular width, height and area between S 1 and S 2 (vestibular width t=3.934, P< 0.001; vestibular height t=3.692, P< 0.001; vestibular area t=4.816, P< 0.001). There were significant differences in S 1 vestibular width, S 1 vestibular height, S 1 and S 2 vestibular area between male groups and female groups (S 1 vestibular width: t=2.969, P=0.003; S 1 vestibular height: t=0.316, P=0.049; S 1 vestibular area: t=1.975, P=0.049; S 2 vestibular area: t=2.023, P=0.044). While there was no significant difference in S 2 vestibular width and height between the two gender groups. There were significant differences in S 1 and S 2 vestibular width, height and area between male and female groups ( P < 0.001). There were no significant difference in parameters between the left and right values of the same vestibular site. Conclusion:The parameters of S 1 sacral vestibule are larger than that of S 2. It implies that S 1 was more feasible to insert iliosacral screws than S 2; lesser diameter iliosacral screws should be selected to insert into S 2. The female S 1 vestibule is smaller than the male, so the iliosacral screws placement has more stringent requirements on the selection of the insertion point and the direction of the screw. And the surgeon can utilize the intact contralateral sacral vestibule as the damaged side to proceed the iliosacral screw inserted simulation.

18.
Chinese Journal of Hepatobiliary Surgery ; (12): 206-209, 2022.
Article in Chinese | WPRIM | ID: wpr-932763

ABSTRACT

Objective:To explore the application value of three-dimensional visualization technology in the analysis of anatomic variation of peripancreatic vessels in patients with pancreatic space occupation.Methods:A total of 98 cases in Yijishan Hospital of Wannan Medical College, the First Affiliated Hospital of University of Science and Technology of China, the First Affiliated Hospital of Anhui Medical University, the Second Affiliated Hospital of Anhui Medical University, the First Affiliated Hospital of Bengbu Medical College, Fuyang People's Hospital from June 2018 to December 2019 were retrospectively analyzed. Of 94 patients were enrolled, including 56 males and 38 females, aged (61.2±7.2) years. Abdominal organs and blood vessels were reconstructed by 3D visualization technology, and anatomic variation of peripancreatic vessels was analyzed, including abdominal trunk, hepatic artery system, portal vein system and dorsal pancreatic artery.Results:The three-dimensional reconstruction rate of celiac trunk vessels was 100.0% (94/94). The 60 cases of abnormal celiac trunk were as follows: liver and spleen trunk in 5 cases (5.3%), stomach and spleen trunk in 1 case (1.1%), liver, stomach and spleen mesentery trunk in 3 cases (3.2%), liver, stomach and spleen mesentery trunk in 17 cases (18.1%), celiac trunk with one or more inferior phrenic arteries in 34 cases (36.2%). There were 69 cases (73.4%) of Michels type Ⅰ, 2 cases (2.1%) of Michels type Ⅲ, 1 case (1.1%) of Michels Ⅴ, 2 cases (2.1%) of Ⅷ, and 1 case (1.1%) of type Ⅸ of hepatic artery system. There were 17 cases (18.1%) of accessory left hepatic artery from celiac trunk which did not belong to Michels classification. Left accessory hepatic artery originated from left gastric artery and left hepatic artery originated from superior mesenteric artery in 1 case (1.1%), right accessory hepatic artery originated from celiac trunk combined with proper hepatic artery and right anterior hepatic artery combined with gastroduodenal artery originated from right posterior hepatic artery in 1 case (1.1%). Abnormal walking of dorsal pancreatic artery in 3 cases. The inferior mesenteric vein flowed into the superior mesenteric vein in 38 cases (40.4%), and the inferior mesenteric vein flowed into the splenic vein and superior mesenteric vein in 4 cases (4.3%).Conclusion:Three-dimensional visualization technique is helpful to determine the variation of peripancreatic vessels, and has certain significance for accurate preoperative evaluation and surgical guidance of patients with pancreatic space occupation.

19.
Chinese Journal of Hepatobiliary Surgery ; (12): 181-184, 2022.
Article in Chinese | WPRIM | ID: wpr-932757

ABSTRACT

Objective:To study the correlation between biliary angle and hepatolithiasis in liver segment Ⅵ.Methods:A retrospective analysis of the clinical data of 46 patients with liver segment Ⅵ bile duct stones treated at the First Affiliated Hospital of Guangzhou Medical University from January 2017 to January 2021 was carried out. There were 18 males and 28 females, with the age of (55.7±10.5) years. During the study period, 50 patients with cholecystitis were enrolled to form the control group, which consisted of 19 males and 31 females, with the age of (57.4±14.4) years. The angles of the right hepatic duct and the bile duct in segment Ⅵ were measured by the 3D hepatic visualization model. Univariate and multivariate logistic regressions were used to analyze factors correlated with formation of segment Ⅵ bile duct stones.Results:The angles of the segment Ⅵ bile duct (124.5±23.1)° and the right hepatic duct (83.5±14.4)° in the study group were significantly larger than the control group(111.8±27.7)°, (76.9±14.8)°. The difference was significant ( t=2.44, 2.10, P=0.017, 0.039). Analysis showed that the angles of segment Ⅵ bile duct ( OR=1.024, 95% CI: 1.006-1.042, P=0.010) and right hepatic duct ( OR=1.035, 95% CI: 1.005-1.065, P=0.020) correlated with bile duct stones in segment Ⅵ, with greater the angles, greater were the rates of bile duct stones in segment Ⅵ. Receiver operating characteristic curve showed that stones were more commonly formed when the angle of bile duct in segment Ⅵ was over 102.295°. The sensitivity, specificity and area under the curve were 91.3%, 34.0% and 0.631 respectively. Conclusion:The angles of segment Ⅵ bile duct and right hepatic duct were risk factors associated with segment VI bile duct calculi.

20.
Chinese Journal of Radiology ; (12): 68-73, 2022.
Article in Chinese | WPRIM | ID: wpr-932485

ABSTRACT

Objective:To explore the feasibility of three-dimensional CT axial sequence assisted volumetric measurement (CTAS) in evaluating atrial septal defect (ASD).Methods:The patients with single secundum ASD who successfully underwent interventional therapy in Fuwai Hospital from January 2016 to December 2019 were retrospectively collected. The patients underwent coronary CT angiography (CTA) before and on the second day after closures, and DSA examinations during operation. A total of 52 cases met the inclusion conditions, among them, there were 37 patients with large defects which had deficient inferior rims ≤3 mm, and 15 patients with severe pulmonary arterial hypertension that occluded with fenestrated ASD occluder. The CT data of patients before and after operation were reconstructed by CTAS. Then the anatomical structure of ASD before the operation was evaluated, including the long diameter and short diameter of ASD, and the CT three-dimensional volume diameter of ASD was calculated by using the equivalent circle conversion formula of ellipse. The waist diameter of occluder and rims of the ASD were measured after occlusion on postoperative CT three-dimensional volume reconstruction images. Meanwhile, the deployed occluder waist dimension was measured in DSA examination during the operation by simulating the balloon measurement of ASD. Lastly, paired t-test and consistency analysis were carried out among the values of parameters. Results:Before operation, the equivalent circle diameter of ASD was (32.3±5.4) mm measured by CTAS. After ASD occlusion, the size of the waist dimension measured by DSA and CTAS were (32.5±4.9) mm and (32.6±4.9) mm. There were no significant differences between them ( P>0.05). There were also no significant differences for each rims of the ASD pre and post operation on CTAS except for the inferior rims and the total length of atrial septum in superior-inferior direction ( P>0.05). Conclusion:As an alternative to balloon sizing, CTAS can be used as a reference standard to conduct ASD interventional treatment.

SELECTION OF CITATIONS